What external trigger options does the ANPR LUMO have?

Beside the free run mode, which is not trigger based, the ANPR LUMO has 3 options for external triggers:                                            

  1. Digital input
  2. TCP
  3. HTTP

All of these triggers can work in different modes which can be selected in the configuration tabs. The different modes are:

Start – Stop

Starts reading on digital input change or TCP/HTTP trigger and stops reading on digital input change/ TCP/HTTP request.

Start-Time

Starts reading on digital input change/ TCP/HTTP trigger and stops when the specified time has passed

Start-Sequence

Starts reading on digital input change/ TCP/HTTP trigger and stops when the specified sequence frames has passed

Single shot

Starts reading on digital input change/ TCP/HTTP trigger and ends after grabbing one shot

Single line

This mode only counts when digital input is used. The LUMO start reading when the digital input changes from low to high and stops when this input is low again.